EX-WHTC EX-Proof Workswell housing for thermal cameras

Protective housing EX-WHTC EX-Proof Workswell housing for thermal cameras

Workswell EX-WHTC EX-proof protective housing for thermal camera is specially designed for using in various industrial, fire-safety and surveillance applications where strict EX regulations must be met. The housing is suitable for different thermal cameras that can be equipped with smaller or bigger lenses.

Workswell EX-proof housing offers effective protection IP67 against dust, rain, snow and freezing conditions due to integrated heater system and the window from germanium

The main part of the housing is very well optimized for maximum heat dissipation from camera electronics. For this reason is thermal measurement stable even at high operational temperature fluctuations. The open system allows an easy access for installation of different kind of infrared cameras including Workswell WIC, Workswell SMARTIS, FLIR series etc. not exceeding dimensions 82 x 80 x 245 mm.

EX-WHTC EX-Proof Workswell housing for thermal cameras

General information 
AISI 316L stainless steel construction
Passivated and electro-polished external surfaces
Silicone 0-ring seals
Mechanical information
Cable entry2x 3/4” NPT holes for cable entry
SunshieldYes
Internal usable area (W x H x L)80 x 82 x 245 mm
Weight16.5 kg
Germanium window information
MaterialGermanium
Window protectionWindow with protection grid
Spectral range7.5 – 14 μm
DimensionsDiameter 56mm
Thickness10mm
External treatmentScratch resistant (Hard Carbon Coating), Antireflection
Internal treatmentAntireflection
Power supply, Serial interface and heating
Power supply230Vac, 0.34A, 50/60Hz
120Vac, 0.5A, 50/60Hz
24Vac, 2.2A, 50/60Hz
Serial interface1 RS-485 line, half-duplex
HeaterOn Temperature 15 °C ± 4 °C
Off Temperature 22 °C ± 3 °C
Operating environment
Indoor / OutdoorYes
IP protectionEN60529: 1991/A1 2001, IP66/IP67 with cable glands
Operating temperature with heating-40 °C…+60 °C, Relative humidity 10-95% (non-condensation)
Certifications
ATEX (EN 60079-0: 2012+A11: 2013, EN 60079-1: 2014, EN 60079-31: 2014):b II 2G Ex db IIC T6 Gb
b II 2D Ex tb IIIC T85°C Db, Ta -40°C to +60°C
IECEX (IEC 60079-0 : 2011 Ed.6, IEC 60079-1 : 2014 Ed.7, IEC 60079-31 : 2013 Ed.2):Ex db IIC T6 Gb
Ex tb IIIC T85°C Db Ta -40°C to +60°C
INMETRO (ABNT NBR IEC 60079-0:2013, ABNT NBR IEC 60079-1:2016, ABNT NBR IEC 60079-31:2014):Ex db IIC T6 Gb
Ex tb IIIC T85°C Db Ta -40oC a/to +60oC
EAC EX (TR CU 12/2011):Ex II 2G Ex db IIC T6 Gb
Ex II 2D Ex tb IIIC T85°C Db, Ta -40°C/+60°C, IP66/IP67
KCs 16- KABO-0172X - 16- KABO-0171XEx d IIC T6
Ex tb IIIC T85°C

Format Name Size Link